NIPROS/1 FAQ
01
Is NIPROS/1 exclusive for PMW-EX3?
![]()
Yes, it is. It is designed for PMW-EX3. Also the package of NIPROS/1 and PMW-EX3 called
PMWEX3NPAC.But, if Genlock and Camera Paint/Remote Control is not need, the PMW-EX1 may be used.By using converter to convert HDMI to HD SDI, HVR-Z5 or HVR-Z7 is also available, but they do not have Genlock and have LANC for camera control.NIPROS/1 is designed for Sony RCP700 protocol and LANC protocol; we do not guaranty inter operability with other manufactures cameras.
02
What are the components of NIPROS/1?
![]()
- Camera adoptor: PS-270
- Base Station: PS-570
- 4.3 inch LCD monitor
- 2 Headsets
- Connection cables
Note: SMPTE fiber and VCT-14 are not included.
03
What is the maximum SMPTE fiber length?
![]()
Approx. 6,700 feet (2km), with power through SMPTE fiber. Result may vary depending on the fiber cable manufacture and operational circumstances. Note: Longer runs are possible with local power.
04
Is there a rack mount kit for the PS-570?
![]()
Sony service part number for the optional rack mount is: #9570058. Or FEC part number is:RMMNIPROS//A.
05
Which cables are included in the package?
![]()
The NIPROS/1 system includes the following interconnection cables:
-BNC cable x1: approx. 1.37 feet (41cm) for HD-SDI connection
- BNC cable x1: approx. 1.37 feet (41cm) for Time code connection
- BNC cable x1: approx. 1.37 feet (41cm) for Gen lock connection
- 6 pin cable x1: approx. 1.37 feet (41cm) for Return connection
- 8pin remote cable x1: for camera remote connection
- Power cable x1: for camera power supply
- BNC cable x1: 3.3 feet (100cm) for backup
- PS-570 Tally in cable x1:
- Tally cable to connect to another base station x1
- 3 pin AC power cable for PS-570
06
Is a return video monitor included?
![]()
Yes, a 4.3 inch 16x9 monitor with BVS input I/F is included.
07
Are there any DC power outputs are on the PS-270?
![]()
Yes, there two outputs.
One 4pin XLR (DC 12V, 3.5A) and one DC power connector to supply EX camera with power are provided.
08
What is the maximum power supply capacity from PS-270?
![]()
- XLR 4pin:DC 12V, 3.5A: max. (Approx. 40 W)
- 4 pin for Camera DC power supply: max. Approx. 35 W
Total approx 75 W
The value may vary from operational circumstances. (It depends on Temperature, Accessories connected to it and so on)
- Approx 60W for accessories except for PMW-EX3 (75W – 13.5W for PMW-EX3)
09
How can I attach the PS270 to the tripod?
![]()
The optional VCT-14 or VCT-U14 tripod plate must be used.
010
Are there any tally on/off switches on the PS-270?
![]()
Yes. Individual ON/OFF switches for the front and side Tally indicators are provided.
011
How many headsets can I connect to the NIPROS system?
![]()
- x2 on the PS -270
- x2 on the PS-570
Note: The NIPROS/1 and PMWEX3NPAC includes 2 headsets, one for PS-270, the other one for PS-570.
012
Is it possible for customers to adjust the” volume” of all the INCOMs separately?
![]()
Yes, individual headphone level and MIC level are provided for both INCOM.
013
When using headset 1 I/F on the PS-270 as DC12V input, what will happen to PS-270?
![]()
PS-270 is powered by DC12V and one head set is applicable to PS-270.
As a DC powered operation system, not only PS-270 but also PS-570 needs DC 12V power supplied.
And PMW-EX3 needs to be powered by BP-30/60.
When PS-270 is operated by DC 12V power, PS-270 can not supply the enough power to PMW-EX3.
014
Is the camera adaptor PS-270 water proof?
![]()
No. Neither is PS-570.
015
Can I operate the PS-570 with local DC power?
![]()
Yes. PS-570 accepts DC 12V in. In this case, both the base station and camera adapter must be
DC powered. The Ex Camera may be by BP-30/60 battery, too.
016
What happens if the SMPTE optical fiber cable is detached from the PS-570, socket while in DC operation from PS-570?
![]()
The entire signal including power supply is automatically shut off for the safety.
(Update more info later)
017
Is it safe to disconnect or connect the fiber optic cable with the PS-570 power ON?
![]()
This practice is not recommended.
018
While the PC-570 and PS-270 is powered by AC, can we connect the EX camcorder powered by BP-30/60 battery?
![]()
No problem. But it may continue the camcorder’s power consumption, draining the camera battery sooner.
019
Can I use AC 240V power supply for this system?
![]()
Yes, the system automatically adjusts the power supply. The capacity is 85V to 245V.
020
Dose this camera adaptor has T/C In and T/C Out?
![]()
Yes, but for using T/C, it is necessary to choose between T/C, RM or LANK on the PS-570 selector switch.
As a limitation, during this process, you lose the RM or LANC communication to control the camera. When you finish T/C setting, if you need camera control, you have to change the position of selectable Switch to RM or LA (LANC).
Note: Camera continues to run TC by its own internal clock. But TC may drift after prolonged operation. Sp please check TC once in a month.
021
While using camera remote controller via RM or LANK, can we JAM the TC generator?
![]()
No. First Jam Sync the camera’s TC generator then switch back to camera remote.
022
How to set the T/C In Out?
![]()
Please make sure that
1. T/C setting on the Camera is to be FREE RUN.
2. Position of the TC/RM/LA switch on the PS-270 and PS-570 is changed from RM or LANC to TC.
023
My camera remote controller: RM-B150/ 750, MR-B1000 connected to PS-570 does not work, why?
![]()
Please make sure that
1. Camera remote cable is connected firmly between camera and PS-270
2. Position of the TC/RM/LA switch on the PS-270 and PS-570 must be set to RM (for PMW-EX3) or LANC (for HVR-Z7 or HVR-Z5)
024
How many HD-SDI outputs does this system have?
![]()
One HD-SDI signal is transmitted form PS-270 and duplicated into two signals by the PS-570. Thus there are two HD-SDI outputs from PS-570 Base Station.
025
When connecting multiple PS-570, do we have to connect Tally cables among all the Switchers?
![]()
One PS-570 which connected to switcher can get up to 5 Tally signals. You can make cascading connect for Tally - cable. Also, Tally cable is included in the package.
026
Can I connect PS-570 to a CCU?
![]()
Yes. But not all CCU are compatible. So please check the compatibility first.
027
Is it possible to feed the PS- 570 an audio signal form external mixer via the INCOM input line?
![]()
Yes, it is. By using 4 Wire input on the PS-570, it can receive audio from the mixer. The input audio signal level can be adjusted by the volume knob on the front panel.
028
Is it possible for the NIPROS system to be operated under the 32°F(0℃)?
![]()
No, it is not. Required operating temperature for NIPROS system is +32 to 104F° (0℃ to 40℃) If operating the system below +32F°, we recommend using a warm-up bag. We do not guarantee operation outside the recommended range.
029
What is the maximum number of fiber optical cable connection links?
![]()
Proved by measuring, 32links
: Connecting 100m x 12 +50m x 16 +20m x 5 =2100m (7,000 feet)
The value may vary depending on the cable manufacturer’s specification.
030
How Do we store the Fiber optical cable?
![]()
When disconnecting the SMPTE fiber cable from the NIPROS system, cover the Limo connector on the SMPTE cable and NIPROS interface with caps equipped with cable and NIPROS system immediately. Always clean the cable, p following the cable manufacture’s instruction.
031
Is fiber cable water proof?
![]()
It depends on cable itself, please ask manufacturer.
032
Minimum bend radius?
![]()
This spec may vary from cable structure, please ask cable manufactures. SMPTE 311M-1998 (USA standard connector) states: 7x the diameter. Bending the fiber optic cable more than the minimum bend radius affects the transmission characteristics of the fiber, causing signal loss, or even permanent damage.
033
Any caution for transportation or operation?
![]()
This system is a precision instrument and must be handled with care. Continuous vibrations or a strong impact may damage the system.
034
What should we do if we experience trouble on the system?
![]()
First read the operation manual. Then, if you still need to solve the problem,
Please call: Sony Electronics Customer Service
-Eastern Service Facility (Teaneck, NJ): 201-833-5300
-Western Service Facility (Los Angeles, CA): 866-766-9272
035
Can I control the PMW-EX3 from the switcher?
![]()
The EX-3 is designed for operation with the Sony Remote Control models: RM-B750 or RM-B150.
036
What is the Minimum power equipment for camera adopter PS-270
![]()
It is 85V 2A. Also, Maximum is 240V 2A.
The required power level varies from the cable length.
DC138V0.5A 33f (100M)
DC138V07A 155f (500M)
DC138V1A 6670f (2000M)
If customers use the optical cable which we do not guarantee, excessive power loss may happen and cause loss of compunction, error or disability of drive and so on.